6.1 Device Response to the Reset
6.1.3 Response to software reset
The master device does not check the DASP- signal for a software reset. If a slave
device is present, the master device checks the PDIAG- signal for up to 15 seconds
to see if the slave device has completed the self-diagnosis successfully.
After the slave device receives the software reset, the slave device shall report its
presence and the result of the self-diagnostics to the master device as described
below:
PDIAG- signal: negated within 1 ms and asserted within 30 seconds
The asserted PDIAG-signal is negated 30 seconds after it is asserted if the
command is not received.
When the IDD is set to a slave device, the IDD asserts the DASP- signal when
negating the PDIAG- signal.
Max. 31 sec.
Max. 30 sec.
Max. 1 ms.
If the slave device is preset, PDIAG- is checked for
up to 31 seconds.
DASP-
PDIAG-
BSY bit
X"00"
X'3F6' Reg.
X"0C"
or X"04"
Status Reg.
BSY bit
Slave device
Master device
Figure 6.3 Response to software reset
C141-E258
6-5
Summary of Contents for MHW2040AC
Page 1: ...C141 E258 03EN MHW2060AC MHW2040AC DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 266: ...This page is intentionally left blank ...
Page 272: ...This page is intentionally left blank ...
Page 274: ...This page is intentionally left blank ...
Page 276: ......
Page 277: ......
Page 278: ......