C141-E110-02EN
5 - 80
Note:
For transfer of a sector of data, the host needs to read Status register (X'1F7') in order to clear
INTRQ (interrupt) signal. The Status register should be read within a period from the DRQ
setting by the device to starting of the sector data transfer. Note that the host does not need to
read the Status register for the first and the last sector to be transferred. If the timing to read
the Status register does not meet above condition, normal data transfer operation is not
assured guaranteed.
When the host issues the command even if the drive requests the data transfer (DRQ bit is
set), or when the host executes resetting, the device correct operation is not guaranteed.
5.4.3
Commands without data transfer
Execution of the following commands does not involve data transfer between the host and the
device.
•
RECALIBRATE
•
SEEK
•
READY VERIFY SECTOR(S)
•
EXECUTE DEVICE DIAGNOSTIC
•
INITIALIZE DEVICE PARAMETERS
•
SET FEATURES
•
SET MULTIPLE MODE
•
IDLE
•
IDLE IMMEDIATE
•
STANDBY
•
STANDBY IMMEDIATE
•
CHECK POWER MODE
•
FLUSH CACHE
•
SECURITY ERASE PREPARE
•
SECURITY FREEZE LOCK
•
SMART: except for SMART Read Attribute values and SMART Read Attribute Thresholds
•
SET MAX ADDRESS
•
READ NATIVE MAX ADDRESS
Figure 5.5 shows the protocol for the command execution without data transfer.
Status read
Command
BSY
INTRQ
DRDY
~
Parameter write
Figure 5.5
Protocol for the command execution without data transfer
Summary of Contents for MPG3xxxAT
Page 1: ...C141 E110 02EN MPG3xxxAT DISK DRIVES PRODUCT MANUAL ...
Page 3: ...This page is intentionally left blank ...
Page 15: ...This page is intentionally left blank ...
Page 31: ...C141 E110 02EN 3 2 Figure 3 1 Dimensions ...
Page 47: ...This page is intentionally left blank ...
Page 67: ...This page is intentionally left blank ...
Page 177: ...This page is intentionally left blank ...
Page 201: ......