1.
Execute the following commands in the Global Zone.
# /usr/sbin/dladm create-aggr -d fjgi0 -d fjgi1 -d fjgi2 2
# zonecfg -z zone2
zonecfg:zone2> set ip-type=exclusive
zonecfg:zone2> add net
zonecfg:zone2:net> set physical=aggr2
zonecfg:zone2:net> end
zonecfg:zone2> exit
(Note) Reboot the Exclusive-IP Non-Global Zone to make this setting effective.
If the Exclusive-IP Non-Global Zone has not booted, execute the following command.
# zoneadm -z zonename boot
If the Exclusive-IP Non-Global Zone has booted, execute the following command.
# zoneadm -z zonename reboot
2.
Execute the following command in the Exclusive-IP Non-Global Zone.
# ifconfig aggr2 plumb 192.168.170.1 up
-
Solaris 11
Example: Adding aggr2 which is a LinkAggregation Group with fjgi0 (this vanity name is net2), fjgi1 (this vanity name is net3),
fjgi2 (this vanity name is net4) to an Exclusive-IP Non-Global Zone (zone1).
1.
Execute the following commands in the Global Zone.
# /usr/sbin/dladm create-aggr -l net2 -l net3 -l net4 aggr2
# zonecfg -z zone2
zonecfg:zone2> set ip-type=exclusive
zonecfg:zone2> add net
zonecfg:zone2:net> set physical=aggr2
zonecfg:zone2:net> end
zonecfg:zone2> exit
(Note) Reboot the Exclusive-IP Non-Global Zone to make this setting effective.
If the Exclusive-IP Non-Global Zone has not booted, execute the following command.
# zoneadm -z zonename boot
If the Exclusive-IP Non-Global Zone has booted, execute the following command.
# zoneadm -z zonename reboot
2.
Execute the following command in the Exclusive-IP Non-Global Zone.
# ifconfig aggr2 plumb 192.168.170.1 up
-
For more information about Solaris Containers, please refer to "System Administration Guide: Solaris Containers-Resource
Management and Solaris Zones" of Oracle Documentation.
- 72 -
Summary of Contents for PCI Gigabit Ethernet
Page 10: ...Figure 1 1 1000Base SX 2ports SE0X7GD2X Figure 1 2 10 100 1000Base T 2ports SE0X7GD1X 4 ...
Page 11: ...Figure 1 3 10 100 1000Base T 4ports SE0X7GQ1X Figure 1 4 10 100 1000Base T 4ports SE0X7GQ2X 5 ...
Page 13: ...Figure 2 1 SE0X7GD2X with Multimode Optical Fiber Cable 7 ...
Page 14: ...Figure 2 2 SE0X7GD1X with Twisted Pair CAT5e Cable 8 ...
Page 15: ...Figure 2 3 SE0X7GQ1X with Twisted Pair CAT5e Cable 9 ...
Page 16: ...Figure 2 4 SE0X7GQ2X with Twisted Pair CAT5e Cable 10 ...