SVmco User Guide
289
Warning
Action:
( / / /S)
05380
configuration file error (%1,%2)
Meaning:
There is no definition file for the half/full down detection threshold setting for the
PRIMECLUSTER linkage function, or the file has a description error. The
operation is performed with the default settings.
%1 = File name (character string. Full path)
%2 = Detailed error code (4-digit numerical value)
5408: A configuration file error occurred. Confirm the existence and format of
the configuration file.
5409: No section/member was found. Confirm that the section/member
definition is correct.
5410: The magnitude relationship between the members is invalid. Check the
magnitude relationship between the setting values.
5411: A setting value is invalid. Confirm the setting value.
5412: A setting value is outside its range. Check the range of the setting value.
Corrective action:
Check the configuration file. If the problem persists, contact your sales
representative or a field engineer.
Severity: