SVmco User Guide
429
12063
lpfc:xxxx:xx:xx.x Adapter error (writel: Detected PCI parity error. Retries
exhausted) vendor-id=10DF device-id=%d revision=%r
Meaning:
A parity error was detected during writel, and retries were performed, but the
operation ran out of retries. (PC error recovery)
%d: (Example) F980
%r: Numerical value (1 to 3 digits)
Corrective action:
If a retry with the succeeding driver is successful, no action is necessary. If it
fails, replacement of the HBA may be necessary or the PCI bus may have a fault.
Contact your sales representative or a field engineer.
If the error recurs after the retry, contact your sales representative or a field
engineer.
Severity:
Warning
Action:
( / /T/S)
12064
lpfc:xxxx:xx:xx.x Adapter error (Suspect any fixed hardware failure)
vendor-id=10DF device-id=%d revision=%r
Meaning: