SVmco User Guide
687
18501
SV RAID:%2 Adapter error (BBU temperature unstable) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
An abnormal battery temperature was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView RAID. If a fan failure occurred, take
corrective action for the target unit. For details on how to check the status in
ServerView RAID, see the
ServerView Suite ServerView RAID Management
User Manual
.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.
Severity:
Error
Action:
(R/M/T/S)
18502
SV RAID:%2 Adapter error (BBU temperature above threshold) vendor-
id=1000/1734 device-id=%d revision=%r