SVmco User Guide
729
SV RAID:%2 Device error (State change on disk from operational to offline)
Meaning:
The HDD state changed from offline to failed.
%2: Device name
Corrective action:
Replace the failed HDD. Perform a rebuild.
Severity:
Error
Action:
(R/M/T/S)
18566
SV RAID:%2 Device error (State change on disk from rebuilding to offline)
Meaning:
The HDD state changed from rebuilding to offline.
%2: Device name
Corrective action:
Replace the offline HDD. Perform a rebuild. For multi-dead, take corrective
action according to the multi-dead recovery procedure.
Severity:
Warning