MMB Web-UI (Web User Interface) Operations
1.2 [System] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E
124
CA92344-0539-04
TABLE 1.46 Button of [IOB#x] Screen
Buttons
Description
On
Turns on the Location LED by clicking [On] button.
Off
Turns off the Location LED by clicking [Off] button
Status Clear
Clears the error status of IOU#x
When you click [Status Clear], the error message of the IOU gets cleared and it is possible to specify the
IOU at the time of next reboot. If error is detected again at the time of reboot, the error status of the IOU gets
registered once again.
(1) Menu Operation
[System]
– [IOU] – [IOU#x]
(2) Window Operations
1.
Click the [Status Clear] button.
Confirmation dialogue box is displayed.
2.
Click the [Apply] button. Click the [OK] button to clear the error status and click the [Cancel] when you
do not want to clear the error status of the IOU.
[Message]
This section describes the messages to be displayed on this window.
Message Number
Message
I_00029
Status Clear completed.
E_00123
Failed to clear the status.
For details on the messages displayed on the window, see
PRIMEQUEST 2000 Series Message Reference
(CA92344-0540).