MMB CLI (Command Line Interface) Operations
2.2 Setting Commands
411
CA92344-0539-04
Too few arguments argc=%d.
The specified parameter is invalid. %s
Missing mandatory options.
The specified controller is not found.
Port and cascade number is required in the parameter since more than 2 enclosures are connected.
Internal error [%d:%d].
The operation is failed. %s
Unable to execute the command because the %s is under maintenance.
Unable to process raid operation because you have not authority to access to the system assigned to the raid
controller.
Unable to process raid operation because you have not authority to access to the Partition#%d assigned to the
raid controller.
(5) Technical notes
Some policies of logical drive cannot be changed from default value when the logical drive is created. If
you want to change these parameter, you should use
“modify raid policy” command after created the
logical drive. These policies are set default values in the table below
Parameter
Default value
Selectable values
Read Policy
No Read Ahead
No Read Ahead, Read Ahead
Write Policy
Write Back
Write Back, Write Through, Force Write Back
I/O Policy
Direct
Direct, Cached
Access Policy
Read/Write
Read/Write, Read Only, Blocked
Drive Cache
Enable
Unchanged, Enable, Disable
When requesting create raid logical_
drive
command
, the
“Internal error [12:0x8017]” or “Internal error
[12:0x802f]” might be returned.
In this case, please verify if the
expected logical drive is created by issuing “show raid logical_drive”
command.
If the expected logical drive is created, ignore the “Internal error”.
If the expected logical drive is NOT created, please try “create raid logical_drive” command again.