MMB CLI (Command Line Interface) Operations
2.2 Setting Commands
417
CA92344-0539-04
2.2.58 delete raid hotspare
Deletes global or dedicated hotspare drive to the specified RAID controller.
Privilege: Administrator, Operator, Partition Operator (Only managed partition)
(1) Input format
delete raid hotspare [SB | DU | IOU | PCI_BOX] <UNIT#>-<PCISLOT#>
disk=[<DISKSLOT#> | <PORT#>-<CASCADE#>-<DISKSLOT#>] {force}
(2) Option
disk: This option specifies disk slot numbers for the internal disks (e.g. disk=0) or port number and cascade
numbers and disk slot numbers for the external disks on disk enclosures (e.g. disk=0-0-0).
force: The command is executed without interactive operation with the user.
(3) Usage example
Example:When you delete a hotspare to a disk attached to slot#0.
# delete raid hotspare SB 0-0 disk=0
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (CA92344-0540).
The command is executed successfully.
The operation is canceled
Too much arguments argc=%d.
Too few arguments argc=%d.
The specified parameter is invalid. %s
The specified controller is not found.
Port and cascade number is required in the parameter since more than 2 enclosures are connected.
Internal error [%d:%d].
The operation is failed. %s
Unable to execute the command because the %s is under maintenance.
Unable to process raid operation because you have not authority to access to the system assigned to the raid
controller.
Unable to process raid operation because you have not authority to access to the Partition#%d assigned to the
raid controller.