Installing the System Into the Rack
Installing the Hardware
4.3.1
Mounting the Assembly Kit
For mounting the server in the PRIMECENTER/DataCenter Rack the following
parts are necessary:
–
support bracket
–
two rails (assembled)
–
eight plugwashers (figure 6 on page 29)
I
The rack assembly kit also contains one stopper bracket (see figure 4)
used for installation in the 3rd-Party Rack only. For installation in the
PRIMECENTER or DataCenter Rack the stopper bracket is not needed
and can be discarded.
Figure 4: Stopper bracket (3rd-Party Rack only)
I
General information are provided in the Technical Manual for the corre-
sponding Rack (see also “Related Publications” on page 141).
For mounting the system into the rack a support bracket must be first mounted
on the rear left support upright of the rack. This bracket must be mounted level
with the lower edge of the device. The bracket is used for the rear fixing of the
left carrier rail.
Ê
Refer to the installation instruction in the technical manual for the relevant
rack model.
Ê
Mark the position of the attachment points of the system on the support
uprights (three height units).
Ê
Mount the support bracket at the appropriate height on the rear left support
upright as described in the technical manual for the relevant rack model.