Summary of Contents for PRIMERGY BX620 S4

Page 1: ...PRIMERGY BX620 S4 2 way Server Blade Operating Manual Edition September 2008 ...

Page 2: ...cumentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1427 002 fm Copyright 2008 Fujitsu Sieme...

Page 3: ...3 Transporting the Server Blade 25 3 4 Environmental protection 26 4 Installing the Hardware 29 4 1 Installation Steps 29 4 2 Unpacking the Server Blade 30 4 3 Installing the Server Blade in the Basic Unit 30 4 4 Connecting the BX620 S4 Server Blade 35 4 4 1 Connecting External Devices 36 5 Installation and Operation 37 5 1 Control and Connection Panel 38 5 2 Switching the Server Blade On Off 41 5...

Page 4: ...6 4 1 Peripheral Configuration 51 6 4 1 1 USB Configuration 51 6 4 2 PCI Configuration 52 6 4 3 CPU Configuration 52 6 5 Security menu 54 6 6 Server Menu 56 6 6 1 ASR R 57 6 6 2 CPU Status 57 6 6 3 Memory Status 59 6 6 4 Console Redirection 59 6 7 Boot Menu 60 6 8 Exit Menu 61 7 Troubleshooting and Tips 63 8 Hot Plug Components 65 8 1 Hard Disk Drives 65 8 1 1 Installing a Hard Disk Module 66 8 1 ...

Page 5: ...es with extended mirroring modular hard disk controller configuration and 2 5 inch SAS or SATA hard disks The new modular hard disk controller concept with four storage module variants allows you to create different configurations with SAS and SATA hard disks for different scenarios The configuration options range from the low cost platform with SATA hard disks up to the high end platform with SAS...

Page 6: ...mentation available on the Internet can be found using the URL http manuals fujitsu siemens com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option If you need a replacement copy of the ServerBooks DVD send the details of your server to the following e mail address Reklamat PC LOG fujitsu siemens com Concept and Target Groups This operating manua...

Page 7: ...he ServerBooks DVD supplied PRIMERGY BX620 S4 Server Blade Options Guide PDF file available on the ServerBooks DVD supplied I The Options Guide describes the server blade expansion and modification options The ServerView Suite contains the ServerStart CD and the ServerBooks DVD as well as the printed version of the PRIMERGY ServerView Suite Server Start manual The manual is also available as a PDF...

Page 8: ...B 1 GB 2 GB or 4 GB fully buffered DIMM 533 MHz or 667 MHz memory modules This allows a maximum memory configuration of 32 GB if 4 GB modules are used Memory Mirroring Mode and ChipKill are standard The standard base configuration has two memory modules so that the server has depending on the DIMM size 1 2 4 or 8 GB on board As there is a total of eight slots available up to six additional memory ...

Page 9: ...cover However they cannot be replaced while the system is running non hot plug the server blade must be switched off How to install replace storage modules is described in the Options Guide LAN Availability The BX620 S4 Server Blade has three onboard LAN controllers with TOE and iSCSI functionality each with two 1 Gbit s Ethernet channels The Ethernet LAN connection can be implemented via switch b...

Page 10: ...g manual for your basic unit To use the additional I O functionality at least one Fibre Channel pass thru blade or switch blade or an Ethernet pass thru or switch blade must be installed in slot NET3 of the basic unit I You cannot mix different I O modules in a PRIMERGY BX600 S2 or BX600 S3 basic unit How to install I O modules later is described in the Options Guide Graphics Controller The BX620 ...

Page 11: ... operated with software RAID 0 or 1 The onboard RAID controllers on the SAS RAID storage modules by default support RAID levels 0 and 1 thus increasing the system s availability SAS hard disk modules also allow the optional installation of a storage module with RAID level 0 or 1 with extended logging and BBU to further increase avail ability Server Management Server management is implemented using...

Page 12: ... your requirements User friendly menus guide you through the installation of the server operating systems Service and Support PRIMERGY servers have a service friendly modular architecture which allows quick and simple maintenance The flash EPROM program supplied with the utilities from Fujitsu Siemens Computers enables fast BIOS updating via the USB interface Global Flash also allows the BIOS and ...

Page 13: ...mands or menu items Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips ...

Page 14: ...J h Product safety and ergonomics IEC 60950 1 EN 60950 1 UL CSA 60950 1 CNS 14336 GB 4943 EN 50371 Electromagnetic compatibility FCC class A CNS 13438 class A VCCI class A AS NZS CISPR 22 class A GB 9254 class A GB 17625 Interference emissions EN 55022 class A Harmonic current EN 61000 3 2 Flicker EN 61000 3 3 Interference immunity EN 55024 EN 300386 CE marking to EU directives Low Voltage Directi...

Page 15: ...tion Ambient conditions Condensation during operation must be avoided Width 286 mm Depth 470 mm 520 mm incl handles and plugs Height 43 mm 1 slot in basic unit Environment class 3K2 Environment class 2K2 EN 60721 IEC 721 Part 3 3 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 5 C 35 C Transport 2K2 20 C 60 C Humidity 10 85 ...

Page 16: ... cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1429 002 fm ...

Page 17: ... for damage sustained during transport and that the delivery corresponds to the specifications in the delivery note see section 4 2 on page 30 Ê Familiarize yourself with the control and display elements on the front of the server blade see chapter Installation and Operation on page 37 Ê Install the operating system and the applications on the server blade To do this you have the following options...

Page 18: ...pported by ServerStart you can of course install it directly without ServerStart I For more information on the remote or local installation of server blades see the ServerStart manual which contains a Quick Start Guide and a detailed description of the individual installation options and wizards A printed copy of the ServerStart manual is contained in the ServerView Suite which is supplied with th...

Page 19: ...whether you can set up the device in your particular environment please contact your sales outlet or our customer service center V CAUTION The activities described in these instructions may only be performed by specialist technical personnel Repairs to the device may only be carried out by authorized specialist personnel Any unauthorized opening and improper repairs could expose the user to risks ...

Page 20: ... in the basic unit operating manual see Related Publications on page 75 If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors Data cables must be adequately shielded The EN 50173 and EN 50174 1...

Page 21: ...ectromagnetic compatibility and those relating to telecommunication terminals If you install other expan sions they may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g lightning symbol may only be opened remov...

Page 22: ... can break at high drive speeds data loss Under certain circumstances sharp CD DVD fragments can pierce the cover of the CD DVD drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck I You can prevent mechanical damage and damage to the CD DVD drive as well as premature CD DVD wear by observing the following sugges tions ...

Page 23: ...in accordance with local regulations concerning special waste The battery must be disposed of in accordance with local regulations concerning special waste Replace the lithium battery on the system board in accordance with the instructions in the service supplement for the server blade All batteries containing pollutants are marked with a symbol a crossed out garbage can In addition the marking is...

Page 24: ... discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction paths o...

Page 25: ...onformity 3 3 Transporting the Server Blade V CAUTION Transport the server blade only in its original packaging or other suitable packaging which will protect it against shock or impact Unpack the server blade only at the place where you want to set it up The system complies with the requirements of the EC directives 2004 108 EC regarding Electromagnetic Compatibility and 2006 95 EC Low Voltage Di...

Page 26: ...needed as well as during long breaks and after completion of work Packaging information Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations In accor...

Page 27: ...emens Computers GmbH Recycling Center D 33106 PaderbornGermany Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EG on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used equipment and is valid across the EU When returning y...

Page 28: ... cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1431 002 fm ...

Page 29: ...blade must be given time to acclimatize to its operating environment acclimatization time before commencing operation 4 1 Installation Steps The following installation steps are described in detail in the following sections of this chapter Unpacking the system see 4 2 on page 30 Installing the server blade in the basic unit see 4 3 on page 30 Connecting the server blade see 4 4 on page 35 Temperat...

Page 30: ...livery note The type label is located at the front right on the underside of the server blade If the delivery is damaged or does not match the delivery note contact your supplier immediately Ê Notify your supplier immediately if you discover any transport damage or if the packaging content does not match the delivery note 4 3 Installing the Server Blade in the Basic Unit The BX620 S4 Server Blade ...

Page 31: ...nts To add a server blade you must first remove the dummy module from the corre sponding slot Figure 3 Removing the dummy module for a server blade Ê Undo the locking mechanism of the handles by pressing the inside touch points of the two handles 1 at the same time This undoes the locking handles of the dummy module Ê Swivel the top handle upward and the bottom handle downward 2 simulta neously un...

Page 32: ... ATTENTION Make sure you observe the safety notes and the information on handling electrostatic sensitive devices in the section Modules with Electrostatic Sensitive Devices on page 24 Server blade boots automatically after installation in a switched on BX600 S3 basic unit with management blade S3 If you insert a BX620 S4 server blade into a switched on BX600 S3 basic unit with management blade S3...

Page 33: ...blade by first pressing the green inside touch points of the two handles 1 at the same time Ê Then turn the locking handles outward 2 into the unlocked position Ê Hold the locking handles in the unlocked position and push the server blade as far as possible into the slot I Make sure you install the server blade in the correct direction The control panel A must be at the top 1 1 2 2 A ...

Page 34: ... 002 fm Figure 5 Final engaging of the locking mechanism Removing the BX620 S4 Server Blade Remove the server blade in the same way as the dummy module see Removing the Dummy Module on page 31 V ATTENTION If a server blade has been removed and no new blade is installed in its place you must install a dummy module in the empty slot Ê Press the locking handles inward until the locking mechanism enga...

Page 35: ...e server chassis connections to the following modules on the back of the basic unit are made automatically by means of plug connectors Power supply units Management blade s for server administration KVM blade for connecting a monitor keyboard and mouse Ethernet switch blade s and or pass thru blades for connecting to the LAN Fibre channel switch blades or pass thru blades for connection to a SAN o...

Page 36: ... has a combined USB VGA port on the front 1 Figure 6 USB VGA connection on the BX620 S4 Server Blade and special cable Connecting an external device via the USB VGA port of the server blade requires a special cable with two USB plugs 2 and a VGA plug 3 I The USB VGA cable is supplied with the basic unit For information on connecting external devices via the infrastructure module of the basic unit ...

Page 37: ...ou have installed it in the basic unit The position and function of the elements on the control and connection panel of the server blade are described in section 5 1 on page 38 The different possible ways of switching the server blade on and off are described in section 5 2 on page 41 Section 5 3 on page 42 explains how to configure the server blade with ServerStart Section 5 4 on page 44 explains...

Page 38: ...sellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1433 002 fm 5 1 Control and Connection Panel Figure 7 BX620 S4 Server Blade control panel The following display control and connection elements are available figure 7 on page 38 1 2 4 3 5 6 7 8 9 ...

Page 39: ...ndby mode ACPI function or in a critical state Flashes green dark orange Server blade is in standby mode ACPI function and selected for identification or this server blade is in a critical state 2 On Off button fully compatible with the Advanced Configuration Power Interface ACPI If you press the On Off button when the BX600 S2 or BX600 S3 basic unit is on 5 V standby voltage is present and the se...

Page 40: ...eactivated to save energy 4 KVM button keyboard video mouse Pressing this button switches the keyboard monitor and mouse to this server blade 5 I O status of the optional I O module green LED I O Dark System is off or signal synchronization has failed Green System is switched on and online 6 NIC indicator green LED Dark System or server blade is off and LAN interface is not active Glows green Exis...

Page 41: ... For detailed information see the basic unit operating manual see Related Publications on page 75 Switching the Server Blade On Off via the Control Panel The basic unit must be switched on You can switch the server blade on or off using one of the following methods To switch the server blade on press the On Off button of the server blade position 2 in figure 7 on page 38 To switch the server blade...

Page 42: ... optional RemoteDeploy software package can be obtained from the Fujitsu Siemens customer service center order number U15000 C180 Reference Installation A reference installation of a server blade performed using ServerStart is used as the basis for a clone image The image is created and then used by RemoteDeploy for fast installation and configuration of other server blades I For details on using ...

Page 43: ... Related Publications on page 75 Ê Press the KVM button position 4 in figure 7 on page 38 on the control panel of the server blade to switch the keyboard mouse and the monitor of the KVM blade to the server blade Preparing the Software Booting from the CD ROM drive Boot the relevant server blade from the ServerStart CD to install the operating system In some cases this may require that you change ...

Page 44: ...ays of updating the firmware of the server blade BIOS and the server blade BMC Updating the firmware of the server blade with TFTP For detailed information see the BX600 S2 or BX600 S3 basic unit operating manual see Related Publications on page 75 Updating the firmware of the server blade from a USB floppy disk drive To update the firmware of the BX620 S4 Server Blade from a USB floppy disk drive...

Page 45: ...uit the BIOS setup The following lists illustrate the structure of the BIOS Setup menus The numbers in brackets refer to the pages on which the individual functions are described Main System Overview Version 49 Build Date 49 BIOS Version 49 BMC F W Version 49 System Time System Date 49 Sync RTC with Mgmt Blade 50 Size 50 Advanced Advanced Settings Reset Configuration Data 50 Peripheral Configurati...

Page 46: ...ssword Lock 55 Server Server Configuration ASR R 56 OS Boot Watchdog Timer 57 Boot Retry Counter 57 ASR R Boot Delay Minute 57 After Power Failure 57 CPU Status 56 CPUx Status 58 Hyper Threading Technology 58 USB Configuration 51 Memory Status 56 Memory Mirror 59 DIMM x y 59 Console Redirection 56 Port 59 Protocol 59 Flow Control 59 Mode 59 Boot Boot Settings Bootup Num Lock 60 Boot Device Priorit...

Page 47: ... as well as the individual menus and possible settings 6 1 Entering the BIOS Setup Ê Start the server blade cold or warm start Ê Press the F2 function key Ê Enter the Setup password if defined and confirm your entry by pressing Enter 6 2 Navigating in the BIOS Setup The BIOS Setup screen has the following structure Figure 8 Main menu ...

Page 48: ...ates that a menu item contains submenus To display a submenu select the relevant menu item and press Enter Pressing ESC returns you from the submenu to the superordinate menu Square brackets enclosing a parameter value indicate that this value can be be changed with the and keys If a parameter consists of multiple input areas e g with time or date specifications you can move between the individual...

Page 49: ...dicates the firmware version of the baseboard management controller System Time System Date Sets the system time and date The system time has the format HH MM SS and the system date has the format day of the weekMM DD YYYY Use the tab keys to position the cursor in the individual input fields I If the system time and date are incorrect after you switch the system off and back on again the lithium ...

Page 50: ...anced menu Reset Configuration Data Defines whether the configuration data is reinitialized when the server blade is started Yes After the server blade is started the plug play functionality identifies the new configuration data initializes the installed boards and drives and the resets this field to No No After the server blade is started the plug play functionality initializes the installed boar...

Page 51: ...ontains the following items USB Devices Enabled Indicates the number of the connected USB devices If no USB device is connected this field shows None USB Functions Defines whether the USB hardware is switched on 4 USB Ports or off Disabled If this menu item shows Disabled the USB controller is not recognized by an operating system and you cannot operate any USB devices USB 2 0 Controller Defines w...

Page 52: ...bmenu are used to define whether the BIOS of the relevant devices is started during the POST Enabled or not Disabled I If you want to boot from one of these devices the corresponding BIOS must be started 6 4 3 CPU Configuration The menu items in this submenu allow you to define the CPU settings Hardware Prefetcher Defines whether the hardware prefetcher of the CPU is Enabled or Disabled Default is...

Page 53: ...being able to activate the Execute Disable feature of the processor Default is Enabled Intel R SpeedStep tm tech Enhanced SpeedStep is an energy saving mode exclusively reserved for processors with Enhanced SpeedStep technology When the processor is not working at full capacity the clock frequency and the supply voltage level of the processor may be reduced This leads to a lower power consumption ...

Page 54: ...a window is opened in which you can define a supervisor password The supervisor password ensures that only autho rized users are granted write access to the BIOS Setup To delete a supervisor password open the password definition window and press Enter twice Change User Password When you press Enter a window is opened in which you can define a user password Users with a user password only have read...

Page 55: ... locked during the installation of adapter cards Enabled or not Disabled I If there is a supervisor password but no user password has been defined or an existing user password has been deleted and Password Check is set to Setup you can only access the BIOS Setup as a supervisor Password Check is set to Always you can only start the system as a supervisor If there is a user password but no supervis...

Page 56: ...12 Server menu ASR R Opens a submenu for defining the restart behavior after a shutdown due to an error CPU Status Opens a submenu for setting the CPU status Memory Status Opens a submenu for activating and deactivating memory modules Console Redirection Opens a submenu for setting up terminal communication System Information Opens a submenu which contains information on the CPU and the MAC addres...

Page 57: ...e in minutes to be waited when OS Boot Watchdog Timer is set to Enabled Timer Count Action Defines the behavior when OS Boot Watchdog Timer is set to Enabled Power Cycle No Action Reset Power Off Boot Retry Counter Defines the maximum number of attempts 1 7 or No Retry to start the operating system This parameter depends on the one hand on the setting of the OS Boot Watchdog Timer parameter On the...

Page 58: ... always used when the system is started If all CPUs are installed and set to Disabled the first CPU is used Even if only one of the two possible CPUs is installed the status indicators are displayed for all possible CPUs Hyper Threading Technology Defines whether the operating system can use all the logical processors within a physical processor Enabled or only the first logical processor Disabled...

Page 59: ... by the system the status of the relevant memory bank is automatically set to Disabled 6 6 4 Console Redirection The Console Redirection submenu contains the following items Port Defines the port used for communication with the terminal On board COM A or Disabled The Disabled setting switches off the terminal functionality and makes the other parameters of this submenu disappear Protocol Defines t...

Page 60: ... If Num Lock is set to On the keyboard is set to Num Lock after booting the Num LED glows Boot Device Priority Opens a submenu for defining the order in which the existing devices are searched for the system files that the system BIOS requires for booting Hard Disk Drives Opens a submenu for defining the order in which the existing hard disk drives are searched for the system files that the system...

Page 61: ... parameter changes and terminates the BIOS Setup Discard Changes and Exit Discards all parameter changes and terminates the BIOS Setup Load Previous Value Resets all the parameters to the values that were in effect when the BIOS Setup was called up Get Default Values Resets all the parameters to their default values ...

Page 62: ... cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1434 002 fm ...

Page 63: ...rect it as described in the chapter Troubleshooting and Tips in the BX600 S2 or BX600 S3 basic unit operating manual see Related Publications on page 75 in the chapters for the installed components in the documentation for the connected devices in the help systems of the individual programs used If you are unable to correct the problem proceed as follows Ê Make a note of the steps you have taken a...

Page 64: ... cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1435 002 fm ...

Page 65: ...om the basic unit except when installing a storage module so that the cover can be opened For a detailed description of the required procedure see the Options Guide or the Service Supplement 8 1 Hard Disk Drives You can install up to two hot pluggable 2 5 inch SAS or SATA hard disk modules in a BX620 S4 Server Blade Defective hard disk modules can also be replaced while the system is running V Att...

Page 66: ...e installing a hard disk module Figure 15 Dummy module Press together the two tabs on the dummy module until the locking mechanism A is released and pull the dummy module out of the bay V ATTENTION Keep the dummy module for future use If the hard disk module is removed again and not replaced with a new one the dummy module must be reinstalled to comply with EMC regulations cooling require ments an...

Page 67: ...ives Installing the Hard Disk Module Figure 16 Hot pluggable hard disk module Press the green ejection tab 1 to the left and open the locking lever 2 Keeping the locking lever open push the hard disk module as far as possible into the bay of the server blade 2 1 ...

Page 68: ...e LED on the hard disk module is glowing continuously i e when an error has occurred V ATTENTION Never remove a hard disk module during operation if you are not sure that the hard disk module belongs to a disk array that operates at RAID level 1 i e the disks are mirrored To replace a hard disk module during operation proceed as follows Ê Press on the green ejection tab in the direction of the pun...

Page 69: ...under Installing the Hard Disk Module on page 67 V ATTENTION If you have removed the hard disk module and do not replace it with a new one the dummy module must be reinstalled to comply with EMC regulations cooling requirements and fire protection measures Make sure that the dummy module engages properly in the bay ...

Page 70: ... cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1436 002 fm ...

Page 71: ...dvanced Technology Attachment BIOS Basic Input Output System CD Compact Disk COM Communication CPU Central Processing Unit DBMS Database Management System DC Dual Core DDR Double Data Rate RAM DIMM Dual Inline Memory Module DVD Digital Versatile Disk ECC Error Correcting Code EDC Error Detection Code ...

Page 72: ...437 002 fm EMC Electromagnetic Compatibility ESD Electrostatic Discharge FBD Fully Buffered DIMMs FC Fibre Channel FSB Front Side Bus GAM Global Array Manager HDD Hard Disk Drive HU Height Unit I O Input Output ID Identification IDE Integrated Drive Electronics IP Internet Protocol iSCSI Internet Small Computer System Interface over IP LAN Local Area Network ...

Page 73: ...Network Interface Card NMI Non Maskable Interrupt PCI Peripheral Component Interconnect PDA Prefailure Detection and Analyzing POST Power On Self Test PSU Power Supply Unit RAID Redundant Arrays of Independent Disks ROM Read Only Memory SAN Storage Area Network SAS Serial Attached SCSI SATA Serial Advanced Technology Attachment ...

Page 74: ...ndungsdaten FCT tim_local work WALTER OBJ_DOKU 1437 002 fm SCA Single Connector Attachment SCSI Small Computer System Interface SCU Server Configuration Utility SFP Small Form Factor Pluggable TOE TCP IP Offload Engine USB Universal Serial Bus VGA Video Graphics Adapter VPD Vital Product Data WOL Wakeup on LAN ...

Page 75: ... on the Internet can be found at the URL http manuals fujitsu siemens com The server PRIMERGY documentation can be accessed using the Industry standard servers navigation option 1 Safety notes and other important information 2 Ergonomics 3 Warranty 4 Returning used devices 5 Quick Start Software Quick Installation Guide Leaflet 6 DataCenter Rack Technical Manual 7 Integrated SAS for RAID Users s G...

Page 76: ...erView Suite ServerStart User Manual 15 PRIMERGY ServerView Suite ServerView S2 Servermanagement User Manual 16 PRIMERGY ServerView Suite ServerView Servermanagement User Manual 17 ServerView RAID User Manual 18 Integrated RAID for SAS User s Guide 19 PRIMERGY RemoteDeploy User Guide 20 PRIMERGY BX Blade Server Systems LAN Switch Blade User Interface Description User Guide 21 PRIMERGY BX Blade Ser...

Page 77: ...es 26 CPU 8 D data manipulation 6 data security 10 delivery note 30 disposal of devices 27 dummy module install 31 server blade 31 E ECC 10 electrical specifications 14 electromagnetic compatibility 14 25 electrostatic sensitive devices ESD 24 EMC directive 14 environment class 15 environmental protection 26 Error Correcting Code 10 ESD electrostatic sensitive devices 24 F Fibre Channel 9 firmware...

Page 78: ...rver ambient conditions 15 compliance standards 14 dimensions 15 electrical specifications 14 safety standards 14 technical data 14 transport 25 ventilation space 15 weight 15 server blade 65 connection panel 38 control elements 38 control panel 38 dummy module 31 hard disk drives 8 65 indicator elements 38 memory 8 server management 11 ServerStart 12 reference installation 42 ServerView 11 suppor...

Page 79: ...BX620 S4 Operating Manual 79 Index V ventilation space 15 W weight 15 ...

Page 80: ... cognitas Gesellschft für Technik Dokumentation mbH 2008 Pfad W Anwendungsdaten FCT tim_local work WALTER OBJ_DOKU 1439 002 fm ...

Page 81: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...