200
Chapter 7 Installing Internal Options
How to remove the internal hard disk unit
1
Turn off the Server Blade.
→
"3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide"
2
Touch a metal part of the Chassis to discharge static electricity.
3
Remove the internal hard disk unit.
While pressing the tab, open the cover, and pull out the internal hard disk unit.
To remove the internal hard disk unit, use both hands to pull it out.
4
Install a new internal hard disk unit or a dummy unit.
"7.7.3 How to Install the Internal Hard Disk Unit" (pg.199)
Replacing the failed internal hard disk unit
When RAID (RAID1) is configured with this server, a failed hard disk unit can be replaced and the
restoration can be performed without turning off the server and peripheral devices (hot swappable/hot
pluggable).
For more details on the replacement procedure, refer to the manual in the Array controller Document &
Tool CD.
For more details on the RAID, also refer to the manual in the Array controller Document & Tool CD.
Tab
Cover
(1)
(2)
Summary of Contents for PRIMERGY BX620 S4