BX920 S4
Upgrade and Maintenance Manual
201
Processors
9.5
Handling processor heat sinks
9.5.1
Required tools
●
Preliminary and concluding steps: tool-less
●
Installing or removing the processor heat sink:
– Phillips PH2 / (+) No. 2 screw driver
9.5.2
Preliminary steps
Before installing, removing or replacing the processor heat sink, perform the
following steps:
Ê
Shut down the server blade as described in section
Ê
Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 55
.
Ê
If necessary, remove the memory modules as described in section
"Removing a memory module" on page 176
.
Ê
Open the server blade as described in section
.
Field Replaceable Units (FRU)
Average task duration: 15 minutes