BX920 S4
Upgrade and Maintenance Manual
253
Server blade
Ê
Install the heat sinks in the new server blade, see section
processor heat sinks" on page 201
Ê
Remove the mezzanine cards carrier with the installed mezzanine card(s)
from the defective server blade, see section
.
Ê
Remove the memory modules from the defective server blade and install it
into the new server blade and install it into the new server blade, see section
"Replacing memory modules" on page 178
Ê
If the SAS backplane is installed, remove the SAS backplane from the
defective server blade and remove the SATA backplane from the new server
blade as described in section of
"Removing the HDD/SSD backplane" on
.
Ê
Install the SAS backplane to the new server blade as described in section of
"Installing the HDD/SSD backplane" on page 115
Ê
If an UFM is installed, remove it from the defective server blade and install
it into the new server blade, see section
"Replacing the UFM" on page 222
.
Ê
If an TPM is installed, remove it from the defective server blade and install it
into the new server blade, see section
"Replacing the TPM" on page 235
.
Ê
If an onboard SAS enabling key is installed, remove it from the defective
server blade and install it into the new server blade, see section
.
Ê
Install the mezzanine cards carrier into the new server blade, see section
"Installing mezzanine cards" on page 130
Ê
If an FBU is installed, remove it from the defective server blade, see section
"Removing the FBU (Flash Backup Unit)" on page 155
.
Ê
If an SAS RAID HDD module is installed, remove it from the defective server
blade and install it into the new server blade, see section
SAS RAID HDD module" on page 150
.
Ê
If applicable, install the FBU in the new server blade, see section
the FBU (Flash Backup Unit)" on page 152
.
Ê
Use the cover from the defective server blade and close the server blade,
see section
"Closing the server blade" on page 57
Use the cover from the defective server blade because the COA label is
stuck there.