76
Upgrade and Maintenance Manual
CX400 M4
Basic software procedures
Figure 37: Progress bar (RAID array rebuild)
V
CAUTION!
The system is now operational, however, data redundancy will not be
available until the RAID array rebuild is complete. Depending on the
HDD capacity the overall process can take up to several hours, in some
cases even days.
I
You may notice a slight performance impact during rebuild.
5.2.4
Using the Chassis ID Prom Tool
System information like server name and model, housing type, serial number
and manufacturing data are stored in the chassis interface board.
In order to integrate your system into the ServerView management environment
and to enable server installation using the ServerView Installation Manager,
system data needs to be complete and correct.
After replacing the midplane kit, system information has to be entered using the
ChassisId_Prom
Tool. The tool and further instructions are available to
maintenance personnel from the Fujitsu Technology Solutions Extranet:
http://partners.ts.fujitsu.com/com/service/intelservers/tools
I
For Japan, follow the instructions provided separately.