76
Operating Manual
CX400 M4 Server Enclosure
Troubleshooting and tips
Added drive reported as defective
Cause
Troubleshooting
RAID controller is not
configured for this
drive
The drive was probably installed when the system
was switched off.
Ê
Reconfigure the RAID controller for the drive
using the corresponding utility. Information is
provided in the documentation for the RAID
controller.
or
Ê
Remove and reinstall the drive while the system is
switched on.
If the HDD/SSD continues to be shown as
defective, then replace it (see the "FUJITSU
Server PRIMERGY CX400 M4 Server Enclosure
Upgrade and Maintenance Manual").