13.2.2 Hard disk drives
13.2.2.1 Indicators on the hard disk drives
Figure 156: Indicators on the 3.5-inch HDD (A) and on the 2.5-inch HDD/SSD modules (B)
1 Slot/RAID status indicator
– Does not light: HDD/SSD does not exist
– Lit (green): HDD/SSD exist
– Lit (red): HDD/SSD Faulty (drive defective, needs replacing)
– Flashing (orange/red): HDD/SSD Rebuild (the data is being restored
after changing a drive)
– Lit (orange): HDD/SSD Identify
2 HDD/SSD activity indicator (green)
– Lit: HDD/SSD in active phase (drive active, drive being accessed)
– Does not light: HDD/SSD inactive