CX400 S1
Upgrade and Maintenance Manual
43
Basic hardware procedures
4.3
Removing the server enclosure out of the
rack
V
CAUTION!
For ALL service tasks, remove the CX400 S1 server enclosure out of the
rack and put it on a separate desk, except when you remove / install
HDD, PSU and Server Node!
It is not allowed to draw the CX400 S1 server enclosure partially out of
the rack.
4.3.1
Preliminary steps
Ê
"Shutting down the server node" on page 41
Ê
"Disconnecting the power cord" on page 42
Ê
If applicable, disconnect all external cables.
Ê
If you remove the CX400 S1 server enclosure out of the rack, remove all
HDD, PSU and Server Node from the server enclosure.