14.2.3.3 Indicators on hot-plug PSUs
Figure 189: Indicators on hot-plug PSUs
Indicator
Status
Description
PSU status
indicator
off
No AC power to all PSUs.
green on
+12V output ON and OK
flashing
green (1 Hz)
AC presents / only +12VSB on (PS off) or PSU
in Smart Standby mode
amber on
– AC cord unplugged or AC power lost; with a
second power supply in parallel still with AC
input power
– Power supply critical event causing a
shutdown; OTP, OCP, UVP, OVP, fan fail
flashing
amber (1 Hz)
Power supply warning events where the power
supply continues to operate; OT warning, OP
warning, OC warning, fan warning
flashing
green (2 Hz)
Power supply FW updating