54
Upgrade and Maintenance Manual
GX2460 M1
Basic hardware procedures
Figure 16: Connecting the power cord
Ê
Connect the power cord to the PSU (1).
Ê
If applicable, connect the mains plug to a grounded mains outlet in the
inhouse power supply network.
Ê
Roll the cable tie around the power cord and the handle of the PSU (2).
Ê
Fix the cable tie.
I
It will take about 60 seconds until the server can be powered on.
4.9
Switching on the server
V
CAUTION!
●
Before switching on the server, ensure that the top cover is closed. In
order to comply with applicable EMC regulations (regulations on
electromagnetic compatibility) and satisfy cooling requirements, the
server must not run while the top cover is removed.
●
For more safety information, see chapter
Ê
Press the On/Off button to start up the server.
Ê
Ensure that the power-on indicator is lit green.
Summary of Contents for PRIMERGY GX2460 M1
Page 16: ...16 Upgrade and Maintenance Manual GX2460 M1 Contents ...
Page 26: ...26 Upgrade and Maintenance Manual GX2460 M1 Before you start ...
Page 56: ...56 Upgrade and Maintenance Manual GX2460 M1 Basic hardware procedures ...
Page 78: ...78 Upgrade and Maintenance Manual GX2460 M1 Power supply unit PSU ...
Page 96: ...96 Upgrade and Maintenance Manual GX2460 M1 Hard disk drive HDD and solid state drive SSD ...
Page 108: ...108 Upgrade and Maintenance Manual GX2460 M1 Fans ...
Page 158: ...158 Upgrade and Maintenance Manual GX2460 M1 Expansion cards and riser modules ...
Page 242: ...242 Upgrade and Maintenance Manual GX2460 M1 Appendix A ...
Page 244: ...244 Upgrade and Maintenance Manual GX2460 M1 Appendix B ...
Page 250: ...RAID Card RAID Card HDD Back Plane 411T61300070 SAS MLC1 SAS MLC2 SATA 0 3 SATA 4 7 C17 C17 ...