104
U41147-J-Z156-2-76
Upgrading second SCSI backplane (1-inch HD subsystems)
Appendix
10.4
Upgrading second SCSI backplane
(1-inch HD subsystems)
I
In the basic 1-channel configuration, only one SCSI backplane is
mounted. In the 2-channel configuration, a optional second SCSI
backplane can be upgraded. Before upgrading, the metal cover has to be
removed, and the delivered divider plate has to be mounted.
Ê
Remove the cage for the hard disk drives (see section “Removing the cage
for the hard disk drives” on page 99).
V
CAUTION!
Take care that the cables are not damaged when pulling out the cage.
The cable has to be carefully guided through the divider aperture of
the server.
Figure 50: Removing the metal cover
Ê
With a screwdriver of type TX20, remove the four fastening screws (1).
Ê
Pull the metal cover out of the cage in the direction of the arrow (2).
2
1
1
1
1