U41147-J-Z156-2-76
59
Troubleshooting and tips
Error messages on the control panel
TEMP_SEN#_FAIL
Temperature sensor
no. # defective.
Contact our service organi-
zation.
RED_PSU#_FAIL
Redundant power supply
unit no. # has failed; power
supply redundancy no
longer available.
Exchange the power
supply unit.
PS_RED_LOST
Loss of power supply
redundancy due to
increased power
requirement and/or failure
of a redundant power
supply unit.
Install a supplementary
power supply unit and/or
exchange the defective
power supply unit.
PS_UNIT#_FAIL
Non-redundant power
supply unit no.# has failed.
Exchange the power
supply unit.
PS_OVERLOAD
Power supply unit
overloading.
Contact our service organi-
zation and/or install a
supplementary power
supply unit.
INTRUSION_DETECT Front door was opened.
Close the front door.
#_TOO_LOW
Voltage # to low.
Contact our service organi-
zation.
#_TOO_HIGH
Voltage # to high.
Contact our service organi-
zation.
SERR_ON_PCIBUS# SERR (system error)
occurred on PCI bus no. #.
Check the boards in PCI
bus no. # and possibly
exchange them.
Contact our service organi-
zation.
PERR_ON_PCIBUS# PERR (parity error)
occurred on PCI bus no. #.
Check the boards in PCI
bus no. # and possibly
exchange them.
Contact our service organi-
zation.
Message
Cause
Reaction
Table 2: Messages on the LCD panel
Summary of Contents for PRIMERGY H200
Page 4: ......
Page 5: ...Related publications and index ...
Page 6: ......
Page 10: ......
Page 18: ...8 U41147 J Z156 2 76 Technical data Introduction ...
Page 19: ...U41147 J Z156 2 76 9 Introduction Technical data ...
Page 20: ......
Page 21: ...U41147 J Z156 2 76 11 Introduction Technical data ...
Page 22: ...12 U41147 J Z156 2 76 Technical data Introduction ...
Page 32: ......
Page 71: ...U41147 J Z156 2 76 61 Troubleshooting and tips Error messages on the control panel ...
Page 72: ......
Page 100: ......
Page 140: ......
Page 142: ......
Page 150: ......
Page 152: ......
Page 154: ......