Error messages on the control panel
Troubleshooting and tips
CPU_BOOT_FAILED
Starting of the CPU boot
has failed.
Check CPU for correct
mounting; reboot the
system. If the error
persists, contact our
service organization.
NO_CPU_DETECTED No CPU available in the
system and/or no CPU
detected (not correctly
mounted or CPU termi-
nator module not
installed).
Check CPU(s) and/or CPU
terminator module(s) for
correct mounting.
AC_FAIL
Power failure occurred.
Check the fuses and the
power cable.
POWER_OK
All voltages reached the
proper values.
No error; this message only
provides extra information.
NO_TRANSLATION
Unknown error code
occurred (no translation is
available).
Contact our service organi-
zation.
Message
Cause
Reaction
Table 2: Messages on the LCD panel