66
• Drive Error LED (Amber)
• Tape Error LED (Amber)
• Clean LED (Amber)
Emergency reset
This button resets the drive. If pressed with the tip of a clip or some other thin object the drive is
reset. This is used to forcible eject the data cartridge if it can not be ejected normally.
"2.2.3 How to use forcible ejection when the data cartridge cannot be ejected"(pg.70)
LED Status
Device status
OFF
No errors
Blinking
A hardware error has been detected.
LED Status
Device status
OFF
No errors
Blinking
There is a problem with the data cartridge being loaded.
LED Status
Device status
ON
The cleaning cartridge is in use.
OFF
Cleaning not required.
Blinking
Cleaning required.
If this LED is on, insert a cleaning cartridge into the drive to clean it.
`
Do not use "Emergency reset" under normal circumstances. If "Emergency reset" is
pressed during operation errors will occur in the OS and backup software.