338
Upgrade and Maintenance Manual
RX1330
M3
Appendix
16.2.3.3 Indicator on hot-plug PSUs (slide-in unit)
Figure 245: Indicator on the hot-plug PSUs
Pos. Indicator
Status
Description
1
PSU status
indicator
green
flashing
The server is switched off, but mains
voltage is present (standby mode).
green on
The server is switched on and operating
properly.
orange
flashing
An overload has been detected. The
PSU is still running, but failure might be
imminent.
orange on
An PSU failure has been detected.
Possible causes:
– Over/under voltage
– Overheating
– Fan failure