Concluding steps
▶
"Connecting the power cord" on page 57
.
▶
Only when replacing a PSU in a non-redundant configuration:
.
▶
"Performing a fan test" on page 94
.
Performing a fan test is not needed if the hot-plug PSU is actively
replaced. iRMC runs automatically.
6.4.4
Replacing the power distribution board
(RX1330 M5)
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Suspending BitLocker functionality" on page 69
.
▶
If applicable,
"Removing the front cover with lock" on page 45
▶
"Shutting down the server" on page 46
▶
"Disconnecting the power cord" on page 47
▶
"Getting access to the component" on page 49
Removing the defective power distribution board
▶
"Removing a hot-plug PSU" on page 105
.
Power supply unit (PSU)
108
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...