"Disconnecting the power cord" on page 47
▶
"Getting access to the component" on page 49
Removing the dummy cover
Figure 188: Removing the dummy cover
▶
Pull the dummy cover out of the bay.
CAUTION
▶
Keep the dummy cover for future use.
▶
If you remove the accessible drive again and do not replace it with
a new one, the dummy cover must be reinstalled to comply with
EMC regulations and to satisfy cooling requirements and fire
protection measures.
Installing the ODD
▶
If no ODD has been installed before:
▶
Remove the two screws and take the ODD latch from the chassis (see
There are two directions of installing the ODD latch on the ODD.
In the 2.5-inch HDD configuration with only one HDD backplane, the
ODD latch engages in the ODD lock. In this configuration the ODD latch
is installed in reverse direction.
Accessible drives
248
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...