Server equipped with up to two hot-plug PSUs
In its basic configuration, the server has one PSU that adjusts automatically to
any mains voltage in the range of 100 V - 240 V. Besides the PSU, a second
PSU can be installed optionally to serve as a redundant power supply. If one
PSU fails, the second PSU in the redundant configuration ensures that
operation can continue uninterrupted and the defective PSU can be replaced
during operation (hot-plug).
CAUTION
The server automatically adjusts to a mains voltage in the range from
100 V - 240 V.
▶
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
PSU types
Power class
Power
PSU
1
500 W
AC PSU Platinum
2
900 W
AC PSU Platinum
All different PSUs can be installed, removed or replaced in the same
way.
Assembly rules
–
Mixed assembly of PSUs from different power classes (e.g. class 1 or class
2) within a system is not supported.
–
Mixing of Platinum PSUs within same class and different manufacturer (e.g.
class 1) within a system is supported.
–
Always install a dummy cover into an unused PSU bay to comply with
applicable EMC regulations and satisfy cooling requirements.
–
For a redundant power supply configuration you need always two PSUs with
the same power class.
Power supply unit (PSU)
96
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...