6.4
Redundant power supply
6.4.1
Installing a hot-plug PSU
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools:
tool-less
Preliminary steps
No steps needed.
Removing the dummy cover
Figure 31: Removing the dummy cover
▶
Press in on both release latches (1) and remove the dummy cover (2).
CAUTION
▶
Keep the dummy cover for future use.
▶
If you remove a PSU and do not immediately replace it with a new
one, a dummy cover must be installed in the bay again to comply
with applicable EMC regulations and satisfy cooling requirements.
Power supply unit (PSU)
RX1330 M5
Upgrade and Maintenance Manual
101