Removing a hot-plug PSU
▶
Remove the power cord from the dedicated PSU, see
Figure 36: Removing the PSU
▶
Push the handle of the PSU halfway upward in the direction of the arrow (1).
▶
Press in on the green locking latch (2).
▶
While keeping the green locking latch pressed, pull the PSU out of its bay
(3).
CAUTION
Excessive temperatures could damage system components.
▶
Never leave the bay for the hot-plug PSU empty for more than
two minutes during operation.
Power supply unit (PSU)
RX1330 M5
Upgrade and Maintenance Manual
105