7.2
Basic information
The HDD or SSD and the installation frame together make up the HDD module
or SSD module.
The server is shipped with one of the following HDD or SSD subsystems:
–
3.5-inch HDD subsystem
–
2.5-inch HDD/SSD subsystem
3.5-inch HDD subsystem
Up to four 3.5-inch SAS/SATA HDD modules can be installed. The HDD
module is connected to the HDD backplane wirelessly. This allows HDD
modules to be plugged in or pulled out easily.
Hybrid configurations of SAS and SATA HDD modules are supported in
combination with an optional HDD controller.
For information on RAID controllers controlling the HDD modules, see
"Expansion cards and backup units" on page 179
2.5-inch HDD/SSD subsystem
–
Up to four (RX1330 M5S) or up to eight 2.5-inch HDD / SSD / PCIe SSD
modules can be installed depending on configuration.
The HDD / SSD / PCIe SSD modules are connected to the HDD backplane
wirelessly. This allows HDD / SSD / PCIe SSD modules to be plugged in or
pulled out easily. If the HDD / SSD / PCIe SSD modules are controlled by a
RAID controller, defective HDD / SSD / PCIe SSD modules can also be
replaced during operation.
–
Up to 10 2.5-inch HDD/SSD modules can be installed depending on
configuration.
The HDD/SSD modules are connected to the HDD backplane wirelessly.
This allows HDD/SSD modules to be plugged in or pulled out easily.
If the HDD/SSD modules are controlled by a RAID controller, defective
HDD/SSD modules can be replaced during operation.
Hard disk drive (HDD) / solid state disk (SSD)
120
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...