RAID level
Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
RAID 1
RAID 5
Removing an HDD/SSD module from a RAID 1 or
RAID 5 array will not result in data loss. However,
the removed drive needs to be replaced
immediately by an HDD/SSD module of the same
or larger capacity.
After replacing the HDD/SSD module,
RAID rebuild will be performed as a
background process, see
RAID array rebuild" on page 87
.
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see the "ServerView Suite RAID
Management" user guide.
Removing a 2.5-inch HDD/SSD module
▶
Pinch the green locking clips and open the locking lever, see
▶
Pull the HDD/SSD module out a few centimeters.
▶
Wait about 30 seconds.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
This period is necessary for the RAID controller to recognize that an
SSD module has been removed.
Hard disk drive (HDD) / solid state disk (SSD)
142
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...