7.5.9
Replacing the SAS expander board
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
If applicable,
"Removing the front cover with lock" on page 45
▶
"Shutting down the server" on page 46
▶
"Disconnecting the power cord" on page 47
▶
"Getting access to the component" on page 49
Removing the defective SAS expander board
Figure 105: Disconnecting the power cable
▶
Disconnect the power cable from the HDD backplane.
Figure 106: Disconnecting the cables from the SAS expander board
▶
Disconnect all cables from the SAS expander board.
Hard disk drive (HDD) / solid state disk (SSD)
164
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...