Installing the heat sink
Figure 182: Installing the heat sink
▶
Ensure that the heat sink cooling fins match the direction of the airflow!
▶
Carefully seat the heat sink on the four threaded holes as shown.
CAUTION
▶
Ensure that the screws on the heat sink are properly seated on
the threaded holes.
▶
Fasten it in a crossover pattern with four screws according to the numbering
(torque: 0.6 Nm, not applicable for Japan).
▶
Notice the position of the air flow label.
Concluding steps
▶
"Installing the air duct" on page 66
▶
.
▶
"Connecting the power cord" on page 57
.
▶
"Switching on the server" on page 60
.
▶
If applicable,
"Installing the front cover with lock" on page 61
.
Processor (CPU)
240
Upgrade and Maintenance Manual
RX1330 M5