13.3
Common operation panel (COP)
13.3.1 Replacing the COP
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Software: 5 minutes
Tools:
Phillips PH1 / (+) No. 1 screw driver
Note on system information backup/restore
The COP contains the Chassis ID EPROM that contains system information
like server name and model, housing type, serial number and manufacturing
data. To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is automatically
stored from the system board NVRAM to the Chassis ID EPROM.
CAUTION
For that reason the COP and the system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.
▶
Reconfigure the BIOS/iRMC and restore the system information like
server name, server model, housing type, serial number and
manufacturing data manually by Chassis ID Prom Tool.
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
If applicable,
"Removing the front cover with lock" on page 45
▶
"Shutting down the server" on page 46
▶
"Disconnecting the power cord" on page 47
▶
"Getting access to the component" on page 49
▶
"Removing the air duct" on page 65
Front panel
258
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...