Remove the protective plastic cover from the CPU socket of the new system
board and fit it onto the socket of the defective system board which will be
sent back to spares.
Returned system boards without this cover probably have to be
scrapped.
▶
Remove the TPM, see
"Removing the TPM" on page 301
.
Installing the new system board
▶
Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
▶
Install the CPU on the new system board, see
.
▶
Check the settings on the new system board, see
.
▶
Install the heat sink, see
"Installing the heat sink" on page 240
.
▶
Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel.
▶
Lower the system board carefully into the chassis.
▶
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in
show the
centering bolts).
▶
Fasten the system board with eight screws, see
.
▶
Connect all cables to the system board.
For the cable plans, see
.
Concluding steps
▶
If applicable, install the TPM, see
"Installing the TPM" on page 296
.
▶
If applicable, install the Dual microSD 64GB Enterprise, see
Dual microSD 64GB Enterprise" on page 320
▶
If applicable, install all M.2 SSDs, see
"Installing the M.2 SSD" on page 313
System board and components
RX1330 M5
Upgrade and Maintenance Manual
333
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...