After replacing the system board
▶
Check the SEL log files to verify whether the backup data on the Chassis ID
EPROM has been restored to the system board, see
the System Event Log (SEL)" on page 83
.
Chassis IDPROM: Motherboard Exchange detected
Chassis IDPROM: BMC FW restore successful
Chassis IDPROM: BIOS restore successful
After replacing the front panel or Chassis ID EPROM
▶
Check the SEL log files to verify whether a backup copy of the system board
settings has been transferred to the Chassis ID EPROM, see
clearing the System Event Log (SEL)" on page 83
.
Chassis IDPROM: BMC FW backup successful
5.3.3
Updating expansion card firmware
For Japan:
Follow the instructions provided separately.
After replacing the expansion card, it is essential to upgrade the firmware to
the latest version without connecting any storage devices. The latest
expansion card firmware version is available from the Fujitsu support web
pages at:
https://ts.fujitsu.com/support/
For Japan:
https://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/
Note on the boot watchdog
Before updating expansion card firmware, ensure that the boot
watchdog is disabled, see
"Disabling the boot watchdog" on page 70
.
After updating expansion card firmware, enable the boot watchdog
"Enabling the boot watchdog" on page 80
Fujitsu does not assume responsibility for any damage done to the
server or for the loss of any data resulting from firmware updates.
Basic software procedures
RX1330 M5
Upgrade and Maintenance Manual
77
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...