More information on suitable backup software solutions and related
documentation is available from the Fujitsu web pages.
5.3.5
Resetting the boot retry counter
The boot retry counter is decremented from its preset value every time the
POST watchdog initiates a system reboot. When the value has reached ’0’, the
system will shut down and power off.
Viewing the boot retry counter
The current boot retry counter status is available in the BIOS:
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
the current number of remaining boot attempts
is displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
▶
Exit the BIOS.
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
Please note, if the customer does not know about the original boot retry
values:
If the system boots up and no further errors occur within 6 hours after
that successful boot attempt, the boot retry counter will automatically be
reset to its default value. Please take into account, that the specified
number of boot attempts can only be determined after this period of
time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Basic software procedures
RX1330 M5
Upgrade and Maintenance Manual
79
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...