184
Upgrade and Maintenance Manual
RX2520
M1
Expansion cards and backup units
9.3.1.2
Removing the slot bracket
Figure 85: Removing the slot bracket
Ê
Remove the screw.
Ê
Remove the slot bracket.
V
CAUTION!
Keep the slot bracket for further use.
Always replace slot brackets into unused PCI slot openings to comply
with applicable EMC regulations and satisfy cooling requirements.
9.3.1.3
Installing an expansion card
Ê
Remove the expansion card from its protective packaging.
I
For further instructions regarding controller settings, please refer to
the accompanying documentation.
Ê
If applicable, attach the required slot bracket to the expansion card as
described in section
"Installing a slot bracket" on page 177
.