366
Upgrade and Maintenance Manual
RX2520
M1
System board and components
14.6.2 Removing the defective system board
Ê
Remove all cables from the system board.
Ê
Remove the following components from the system board as shown in the
related sections:
– Heat sink: see
section "Removing processor heat sinks" on page 248
I
Leave the processor on the defective board for now.
– Memory modules: see section
"Removing memory modules" on
page 227
I
Ensure to take note of the memory modules’ mounting positions
for reassembly.
– Expansion cards: see section
"Removing expansion cards" on page 186
I
Ensure to take note of the controllers’ mounting positions and
cable connections for reassembly.
– UFM: see section
"Removing the UFM" on page 340
– onboard SAS enabling key: see section
"Removing the onboard SAS
enabling key" on page 360
– SAS RAID controller: see section
"Removing the SAS RAID controller"
on page 194
Summary of Contents for PRIMERGY RX2520 M1
Page 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Page 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Page 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Page 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Page 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...