4.1.2
Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
–
Global Error
events that need to be resolved by maintenance personnel
–
Customer Self Service
(CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs indicate, if the defective component is a customer
replaceable unit or if maintenance personnel needs to be dispatched to replace
the part.
I
The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1
Global Error indicator
Ê
Check the Global Error indicator on the front or connector panel of the
server:
Ê
For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section
"Viewing the
SEL" on page 90
.
– Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.2.2
Customer Self Service (CSS) indicator
Ê
Check the CSS indicator on the front panel or connector panel of the server:
Summary of Contents for PRIMERGY RX2520 M1
Page 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Page 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Page 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Page 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Page 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...