RX2520 M1
Upgrade and Maintenance Manual
55
Basic hardware procedures
4.4.2
Removing the server from the rack
I
In most cases maintenance tasks can be performed while the server is
extended from the rack. However, depending on accessibility or security
guidelines, it may make sense to completely remove the server from the
rack cabinet for maintenance purposes.
V
CAUTION!
At least two people are needed to lift the server out of the rack cabinet.
(For the Japanese market, please refer to "
安全上のご注意
".)
Additionally, a lifter is required in the following cases:
– The server weighs more than 50 kg.
– The server weighs more than 21 kg and is installed above the height
of 25 U.
For configurations below 32 kg:
At least two people are needed to lift the server
out of the rack cabinet.
For configurations below 55 kg:
At least three people are needed to lift the server
out of the rack cabinet.
For configurations above 55 kg:
At least four people are needed to lift the server
out of the rack cabinet.