Basic software procedures
Ê
Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line interface (Linux only)
The memory error counter can be reset using the
meclear
utility which is part
of the ServerView agents for Linux.
I
meclear
(Memory Module Error Counter Reset Utility) allows to reset
the error count collected for a memory module, for example after it has
been replaced.
For further details, please refer to the
meclear
manual pages.
Ê
Log in as root.
Ê
Enter the command below, followed by
[ENTER]
:
/usr/sbin/meclear
Ê
Select the number of a memory module with a status other than "OK" or
"Not available".
Ê
Repeat the step above until all memory modules show the "OK" status.
Ê
Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
5.2.7.2
Processors
ServerView Operations Manager may report a defective processor in case of a
critical error.
I
Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
Ê
Launch the ServerView Maintenance Tools:
– Windows Server 2008 R2 and below:
Start
>
(All) Programs
>
Fujitsu
>
ServerView Suite
>
Agents
>
Maintenance Tools
– Windows Server 2012 and above:
Start
>
Apps
>
Fujitsu
>
Maintenance Tools
Summary of Contents for PRIMERGY RX2520 M1
Page 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Page 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Page 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Page 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Page 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...