RX2530 M4
Upgrade and Maintenance Manual
149
Hard disk drive (HDD) / solid state drive (SSD)
7.4.2 Configuration with up to eight HDD/SSD modules
I
SAS HDDs must not be populated above or below BC-SAS / BC-SATA
HDDs. In order to avoid this configuration, please make a free bay
intentionally.
For example, if only one SAS HDD or one BC-SAS / BC-SATA HDD is
ordered, this HDD will be installed in position 0 and position 1 will not be
used.
SAS HDDs and BC-SAS / BC-SATA HDDs can be mixed as long as SAS
HDDs are not populated above or below BC-SAS / BC-SATA HDDs.
The same kind of HDDs can be populated above or below each other.
Configuration with onboard SATA/sSATA controller
Figure 66: Configuration with up to eight HDDs/SSDs (onboard controller)
Position Logical drive
number
ServerView RAID Manager display name
LSI Embedded MegaRAID (0)
[0]
0
Vendor Product (0)
[1]
1
Vendor Product (1)
[2]
2
Vendor Product (2)
[3]
3
Vendor Product (3)
LSI Embedded MegaRAID (1)
[4]
4
Vendor Product (0)
[5]
5
Vendor Product (1)
[6]
6
Vendor Product (2)
[7]
7
Vendor Product (3)
Onboard SATA controller
Onboard sSATA controller
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...