RX2530 M4
Upgrade and Maintenance Manual
241
Expansion cards and backup units
9.5.5.2 Replacing the M.2 SSD
Ê
Remove the PDUAL AP200, see section
"Removing the expansion card" on
Figure 156: Removing the M.2 SSD (A)
Ê
Remove the screw (see circle) of the defective M.2 SSD at the bottom side
(1).
I
You can use the iRMC web interface or the ServerView RAID
manager to detect the defective M.2 SSD.
Ê
Pull the bolt out of the hole (2).
Ê
Remove the bolt (3).