266
Upgrade and Maintenance Manual
RX2530 M4
Expansion cards and backup units
9.6.4.2
Removing the FBU with the holder
Figure 186: Removing the FBU with the holder
Ê
Lift up the green locking handle on the holder (see circle) while sliding the
holder in direction of the arrow as far as it will go.
I
After that, the shoulder screw caps on the riser module will rest in the
wide ends of the keyhole slots on the holder.
Ê
Lift the holder out of the riser module 3.
9.6.4.3
Disconnecting the FBU cable from the FBU
Ê
Disconnect the FBU cable from the FBU (see figure
).
9.6.4.4
Removing the FBU from the holder
Ê
Pull the FBU at a slight angle out of the holder (see figure
).
9.6.4.5
Concluding steps
Ê
Install the riser module 3, see section
"Handling riser modules" on page 67
.
Ê
Ê
"Connecting the power cord" on page 63
Ê
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...