RX2530 M4
Upgrade and Maintenance Manual
291
Processor (CPU)
11.2 Upgrading to 2 CPU configuration
V
CAUTION!
– CPUs are modules which are extremely sensitive to electro-static
discharges and therefore must always be handled with care. After a
CPU has been removed from its protective sleeve or from its socket,
place it with its smooth side down on a non-conducting, antistatic
surface. Never push a CPU over a surface.
– Only CPUs of the same type may be used on the system board. That
means the number of the internal CPU cores as well as the primary
clock and the QPI frequency have to be the same.
– For dual operation, use a suitable multiprocessor operating system.
11.2.1 Preliminary steps
Ê
"Suspending BitLocker functionality" on page 77
Ê
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 52
Ê
"Removing the air duct" on page 73
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...