RX2530 M4
Upgrade and Maintenance Manual
299
Processor (CPU)
11.3.1 Preliminary steps
Ê
"Locating the defective server" on page 47
Ê
"Suspending BitLocker functionality" on page 77
Ê
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 52
Ê
"Removing the air duct" on page 73
11.3.2 Removing the heat sink
Figure 206: Removing the heat sink
Ê
Loosen the captive screws (circles) following the sequence described below
and using a #2 screwdriver:
V
CAUTION!
Please do not use an electric screwdriver.
I
There is a possibility the washer on the heat sink mounting screw
may be damaged.
Ensure to follow the removing procedure as below.
1. Loosen the four captive screws one by one (in the sequence 4 to 1)
rotating them a half-turn each.
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...