330
Upgrade and Maintenance Manual
RX2530 M4
Liquid cooling (LC)
Ê
"Switching on the server" on page 66
Ê
"Resuming BitLocker functionality" on page 98
12.4.2 Removing a memory module
12.4.2.1 Preliminary steps
Ê
"Suspending BitLocker functionality" on page 77
Ê
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 52
12.4.2.2 Removing a memory module
Ê
Pull up the required memory cover(s), see figure
.
Ê
Open the required memory cooling unit, see figure
.
– Swing the left/right memory cooling unit(s) in the direction of the pump
(see arrows).
– Swing the central memory cooling unit in the direction of the arrow.
Ê
If applicable, remove the memory spacers.
Ê
Remove the memory module, see section
.
Ê
If applicable, install the memory spacers, see section
Ê
Close the required memory cooling unit(s).
Ê
Position the memory cover(s) over the memory modules and press them
carefully down, see figure
.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver (for the riser module)
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...